Data on working range and substitute value in event of cutout or K bus fault.
Temperature sensor  | 
	Working range  | 
	Substitute value  | 
Heat exchange sensor  | 
	10 °C ... 95 °C  | 
	55 °C  | 
Evaporator sensor  | 
	-10 °C ... 30 °C  | 
	0 °C  | 
Footwell sensor (inner)  | 
	10 °C ... 61 °C  | 
	25 °C  | 
Exterior temperature value  | 
	K-bus  | 
	0 °C  | 
Latent heat accumulator  | 
	0 °C ... 100 °C  | 
	25 °C  | 
Specified temperature  | 
	approx. 16 °C ... approx. 30 °C  | 
	24 °C  | 
Resistance values at an ambient temperature of 25 °C and fault limits.
Temperature sensor  | 
	Resistor R25  | 
	Fault limit  | 
Heat exchange sensor  | 
	10 kOhms +/- 5%  | 
	Temperature > 126 °C or temperature =< 45 °C  | 
Evaporator sensor  | 
	1500 Ohm +/- 2%  | 
	Temperature > 101 °C or temperature =< -46 °C  | 
Footwell sensor (inner)  | 
	10 kOhms +/- 5%  | 
	Temperature > 123 °C or temperature =< -47 °C  | 
Latent heat accumulator  | 
	
  | 
	Temperature > 137 °C or temperature =< 44 °C  |