Independent ventilation
 
The independent ventilation function can be activated in ignition lock position 1 or via pre-programming by means of the multi-information display (MID). Various settings are possible dependent on the ignition lock position.
Statuses at ignition lock 1:
	- Operating unit is active
 
	- Temperature control not active (water valves closed)
 
	- Flap program is adjustable
 
	- Blower is adjustable
 
	- Button block not active
 
Statuses at ignition lock 0:
	- Operating unit not active
 
	- Temperature control OFF (water valves closed)
 
	- Fresh air flap position 100%
 
	- Recirculated air flap position 0%
 
	- Mixing air flap position 0%
 
	- Defrost flap position 0%
 
	- Ventilation flap position 100%
 
	- Footwell/rear area flap position 0%
 
	- Rear area ventilation flap position 0%