Comparison Images EWS Oscilloscope Measurement

Checking data lead from the EWS to the DME/DDE control unit

Oscilloscope measurement with metrology in the DIS

When doing this, proceed as follows:

Important

During the measurement, the DME/DDE must be connected.

The following illustration shows the oscilloscope image of a measurement on a data lead through which the EWS signal is correctly transmitted.

P610003G

Signal OK

Note that the statement "OK" only refers to the data lead and the signal form. It is unable to determine whether the transmitted code is correct.

If it is still not possible to start the engine:

EWS 2, EWS 3.2: Conduct a data comparison EWS-DME/DDE

EWS 3.3: Conduct a EWS-DME/DDE match

P610005G

Signal not OK

The above signal indicates a fault in the DME/DDE.

Continue fault finding in the DME/DDE diagnosis program with the fault symptom "Engine does not start. Work through the test modules offered.

P610004G

Signal not OK

P610006G

Signal not OK

The above signal indicates a short to ground or a line break. Check EWS-DME/DDE data link and repair if necessary. If data link is OK, replace EWS control unit.