Voltage Supply and Main Relay DDE 3.0
 
Function
The voltage supply of the DDE control unit is based on following stages:
	- At ignition ON, voltage is applied to the DDE control unit via terminal 15
 
	- The DDE control unit switches the DDE main relay via S_HR
 
	- The DDE main relay switches terminal 30 via U_HR to the DDE control unit
 
Troubleshooting
The following faults are monitored in the voltage supply system:
	- Fault code 10: Voltage supply to DDE control unit or injection pump exceeded/below specified value
 
	- Fault code 12: Terminal 15
 
	- Fault code 13: DDE main relay switches too early or too late
 
Consequences:
	- Fault code 10: The system switches over from start of injection closed-loop control to start of injection open-loop control and exhaust gas recirculation is deactivated
 
	- Fault code 12: Engine shuts down
 
	- Fault code 13: None