| Pin | Type | Description / Signal type | Connection / Measuring notes | 
|---|
| 1 | E | Voltage supply, terminal 15 | Fuse F20 | 
|   |   |   | 
| 2 |   | Not used |   | 
|   |   |   | 
| 3 | E/A | K-bus signal line | K-bus connector | 
|   |   |   | 
| 4 | E | Signal, switch off consumer load | Connector, switch off consumer load | 
|   |   |   | 
| 5 | A | Left water valve activation | Water valves | 
|   |   |   | 
| 6 |   | Not used |   | 
|   |   |   | 
| 7 | A | Relay activation | Rear defogger relay | 
|   |   |   | 
| 8 | A | Signal Heated windscreen washer jets | Connector, heated washer jets | 
|   |   |   | 
| 9 | A | Auxiliary water pump activation with independent heating Auxiliary water pump activation with latent heat accumulator | Auxiliary water pump with independent heating Connector, auxiliary water pump with latent heat accumulator | 
|   |   |   | 
| 10 | E | Pressure signal | High pressure switch | 
|   |   |   | 
| 11 |   | Not used |   | 
|   |   |   | 
| 12 |   | Not used |   | 
|   |   |   | 
| 13 |   | Not used |   | 
|   |   |   | 
| 14 |   | Not used |   | 
|   |   |   | 
| 15 | A | Air conditioning system standby signal | DDE control unit | 
|   |   |   | 
| 16 | A | Signal, A/C compressor ON (M51) | DDE control unit | 
|   |   |   | 
| 17 | A | Signal, A/C compressor OFF (M51) A/C compressor signal | DDE control unit Digital diesel electronics control unit DME control unit | 
|   |   |   | 
| 18 | E | Relay activation, auxiliary fan stage I | Connector, auxiliary fan stage 1 | 
|   |   |   | 
| 19 |   | Not used |   | 
|   |   |   | 
| 20 | M | Ground High pressure switch | High pressure switch | 
|   |   |   | 
| 21 | A | Supply High pressure switch | High pressure switch | 
|   |   |   | 
| 22 |   | Not used |   | 
|   |   |   | 
| 23 | E | Night light signal | Connector, terminal 58g | 
|   |   |   | 
| 24 |   | Not used |   | 
|   |   |   | 
| 25 |   | Not used |   | 
|   |   |   | 
| 26 |   | Not used |   | 
|   |   |   | 
		
	
	
	
| Pin | Type | Description / Signal type | Connection / Measuring notes | 
|---|
| 1 | A | Relay activation Relay for latent heat accumulator | Relay for latent heat accumulator | 
|   |   |   | 
| 2 | A | Signal, independent heating ON Valve activation Changeover valve LWS | Independent heating relay Solenoid valve independent heating/ventilation II Changeover valve LWS | 
|   |   |   | 
| 3 | A | Independent heating ON feedback | Independent park/auxiliary heating | 
|   |   |   | 
| 4 | A | Sensor signal | NTC resistor, steering angle sensor | 
|   |   |   | 
| 5 | M | Sensor ground | NTC resistor, steering angle sensor | 
|   |   |   | 
| 6 | A | Valve activation Shut-off valve LWS | Shut-off valve LWS | 
|   |   |   |