A11 Heating and A/C control module

Plug connector overview

NumberX-pin, colourDescription
X61026-pin, bluePlug connector 3
X61112-pin, naturalPlug connector 4
X181536-pin, blackPlug connector 5
X183413-pin, blackPlug connector 0

Pin assignments at plug connector X610

PinTypeDescription / Signal typeConnection /
Measuring notes
1EVoltage supply, terminal 15Fuse F20
   
2 Not used 
   
3E/AK-bus signal lineK-bus connector
   
4ESignal, switch off consumer loadConnector, switch off consumer load
   
5ALeft water valve activationWater valves
   
6 Not used 
   
7ARelay activationRear defogger relay
   
8ASignal Heated windscreen washer jetsConnector, heated washer jets
   
9AAuxiliary water pump activation with independent heating Auxiliary water pump activation with latent heat accumulatorAuxiliary water pump with independent heating Connector, auxiliary water pump with latent heat accumulator
   
10EPressure signalHigh pressure switch
   
11 Not used 
   
12 Not used 
   
13 Not used 
   
14 Not used 
   
15AAir conditioning system standby signalDDE control unit
   
16ASignal, A/C compressor ON (M51)DDE control unit
   
17ASignal, A/C compressor OFF (M51) A/C compressor signalDDE control unit Digital diesel electronics control unit DME control unit
   
18ERelay activation, auxiliary fan stage IConnector, auxiliary fan stage 1
   
19 Not used 
   
20MGround High pressure switchHigh pressure switch
   
21ASupply High pressure switchHigh pressure switch
   
22 Not used 
   
23ENight light signalConnector, terminal 58g
   
24 Not used 
   
25 Not used 
   
26 Not used 
   

Pin assignments at plug connector 4 X611

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASensor signalLeft heat exchanger sensor
   
2 Not used 
   
3ASensor signalEvaporator sensor
   
4ASignal Output stageOutput stage
   
5 Not used 
   
6MSensor groundSensor connector
   
7EActuating signal Fresh air flap motorFresh air flap motor
   
8EActuating signal Fresh air flap motorFresh air flap motor
   
9EActuating signal Fresh air flap motorFresh air flap motor
   
10EActuating signal Fresh air flap motorFresh air flap motor
   
11ASensor signalLeft footwell sensor
   
12 Not used 
   

Pin assignments at plug connector 5 X18153

PinTypeDescription / Signal typeConnection /
Measuring notes
1ARelay activation Relay for latent heat accumulatorRelay for latent heat accumulator
   
2ASignal, independent heating ON Valve activation Changeover valve LWSIndependent heating relay Solenoid valve independent heating/ventilation II Changeover valve LWS
   
3AIndependent heating ON feedbackIndependent park/auxiliary heating
   
4ASensor signalNTC resistor, steering angle sensor
   
5MSensor groundNTC resistor, steering angle sensor
   
6AValve activation Shut-off valve LWSShut-off valve LWS
   

Pin assignments at plug connector 0 X18341

PinTypeDescription / Signal typeConnection /
Measuring notes
1EVoltage supply, terminal 30 for throttle actuatorFuse F9
   
2APositive supply, magnetic clutchHigh pressure switch (M51) Solenoid clutch
   
3MGroundGround connector X219