Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | E | Voltage supply, terminal 15 | Fuse F20 |
| | |
2 | | Not used | |
| | |
3 | E/A | K-bus signal line | K-bus connector |
| | |
4 | E | Signal, switch off consumer load | Connector, switch off consumer load |
| | |
5 | A | Left water valve activation | Water valves Left valve |
| | |
6 | A | Right water valve activation | Water valves Right valve |
| | |
7 | A | Relay activation Rear defogger relay | Rear defogger relay |
| | |
8 | A | Signal Heated windscreen washer jets | Connector, heated washer jets |
| | |
9 | A | Auxiliary water pump activation with independent heating, Auxiliary water pump activation with latent heat accumulator | Auxiliary water pump with independent heating, Connector, auxiliary water pump with latent heat accumulator |
| | |
10 | E | Pressure signal | High pressure switch |
| | |
11 | | Not used | |
| | |
12 | E | Signal input | AUC sensor |
| | |
13 | A | Positive activation | AUC sensor |
| | |
14 | | Not used | |
| | |
15 | A | Air conditioning system standby signal | DDE control unit |
| | |
16 | A | Signal, A/C compressor ON (M51) | DDE control unit |
| | |
17 | A | Signal, A/C compressor OFF (M51) A/C compressor signal | DDE control unit DME control unit Digital diesel electronics control unit |
| | |
18 | E | Relay activation, auxiliary fan stage I | Connector, auxiliary fan stage 1 |
| | |
19 | | Not used | |
| | |
20 | M | Ground High pressure switch | High pressure switch |
| | |
21 | A | Supply High pressure switch | High pressure switch |
| | |
22 | A | Shut-down signal With latent heat accumulator: | Connector, auxiliary water pump With latent heat accumulator: |
| | |
23 | E | Night light signal | Connector, terminal 58g |
| | |
24 | | Not used | |
| | |
25 | M | Ground AUC sensor, heating | AUC sensor |
| | |
26 | A | Positive activation AUC sensor, heating | AUC sensor |
| | |
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | A | Signal, independent heating ON Relay activation Relay for latent heat accumulator | Receiver, independent heating Relay for latent heat accumulator |
| | |
2 | A | Signal, independent heating ON Valve activation Changeover valve LWS | Blower relay Changeover valve LWS |
| | |
3 | A | Independent heating ON feedback | Independent heating/ventilation control unit |
| | |
4 | A | Sensor signal | NTC resistor, steering angle sensor |
| | |
5 | M | Sensor ground | NTC resistor, steering angle sensor |
| | |
6 | A | Valve activation Shut-off valve LWS | Shut-off valve LWS |
| | |